Domestic Electrical Appiances

The sale of electrical appliances and equipment around the world is conditional to proving that the product is safe. One of simplest ways of demonstrating that the design, construction and performance of the product is safe, is by testing to a safety standard, whether the regulatory regime is mandatory or not.

Whilst safety standards around the world aim to achieve largely the same thing, they vary in the detail from country to country. At Delhi Test House, our fully equipped laboratories and experienced engineers and technicians can carry out product safety testing for many of the Indian standards.

Air, Ambient Air Quality Monitoring

Testing Parameters Test Methods Testing Range
Leakage Current Test IS 14724 300 µA to 3 A,
High Vage Test IS 14724 Upto 2 kV,
Rate Of Flow IS 14724 Upto 4 lpm
Leakage Tightness IS 14724 0 to 10.6 kg/cm2

2) Mineral Filled Sheathed Heating Element

Testing Parameters Test Methods Testing Range
Marking Visual 0 to 230V AC Upto 6 kW
Protection Against Electric Shock IS 302 (Part 1) Clause. 8 0 to 75 V
Input Test IS 302 (Part 1) Clause. 10 0 to 300V, 0 to 5000 W,
Temperature Rise IS 302 (Part 1) Clause. 11 Ambient (-)400°C,
Electrical Insulation & Leakage Current at Operating Temperature IS 302 (Part 1) Clause. 13 1 MΩ to 1000 MΩ X 106 0 to 750 µA,
Transient Over Vage IS 302 (Part 1)Clause. 14 0 to 8 kV
Moisture Resistance IS 302 (Part 1) Clause. 15 0 to 96 %, Ambient to 199.9°C,
Insulation Resistance and Electric Strength (After Moisture Test) IS 302 (Part 1) Clause. 16 Qualitative, 0 to 3 kV,
Endurance Test IS 302 (Part 1) Clause. 18 Qualitative - Ambient to 300°C
Abnormal Operation IS 302 (Part 1) Clause. 19 Qualitative - Ambient to 300V,
Stability & Mechanical Hazards IS 302 (Part 1) Clause. 20 Qualitative Mass : 60g, Force 20 N
Mechanical Strength IS 4159 Clause. 21 20 N
Construction IS 4159 Clause. 22 Qualitative (Visual)
Internal Wiring IS 4159 Clause. 23 Qualitative (Visual)
Components IS 4159 Clause. 24.2 0 to 300 mm
Supply Connection And External Flexible Cords IS 4159 Clause. 25.1 Qualitative (Visual)
Terminal For External Conductor IS 302 (Part 1) Clause. 26 Qualitative
Provision For Earthing IS 302 (Part 1) Clause. 27 0(-)2 A, 0 to 5V
Resistance To Heat, Fire & Tracking IS 302 (Part 1) Clause. 30 0 to 1000°C, 0 to 500°C
Creepage Distance & Clearance Except Transient Vage IS 302 (Part 1) Clause. 29 0 to 300 mm, 0 to 25 mm
Screws & Connection IS 302 (Part 1) Clause. 28 0.1 to 1.5 Nm
Resistance to Rusting IS 302 (Part 1) Clause. 31 Qualitative - Ambient to 250°C,
Finish IS 302 (Part 1) Clause. 33 Qualitative (Visual)

3) Electric Iron Safety of Household and Similar Electrical Appliances

Testing Parameters Test Methods Testing Range
Rating IS 366 Clause. 6 0 to 230 V ac 0 to 1 kW
Classification IS 302-2-3 Clause. 6 Class I & II
Marking IS 302-2-3 Clause. 7 0 to 230 V ac 0 to 1 kW
Measurement Of Heating Of Time IS 366 Clause. 10 Ambient to 400°C, Upto 20 min
Measurement Sole Plate Temperature IS 366 Clause. 11 Ambient to 400°C
Measurement Of Temperature Distribution IS 366 Clause. 12 Ambient to 400°C
Measurement Of Initial Over Swing IS 366 Clause. 13 Ambient to 400°C
Temperature Heating Up Excess Temperature IS 366: 1991 Clause. 13 Ambient to 400°C
Measurement Of Cycle Fluctuation Of Temp IS 366 Clause. 14 Ambient to 400°C
Measurement Of Temperature Drop Under Load IS 366 Clause. 15 Ambient to 400°C
Measurement Of Thermo Static Stability IS 366 Clause. 16 Ambient to 400°C
Endurance Test Drop Test IS 366 Ambient to 400°C
Finish IS 366 Clause. 17 Qualitative (Visual)
Resistance To Rusting IS 302-2-3 Clause. 31 & IS 366 Cl. 17.3 Ambient to 250°C
Protection Against Access To Live Part IS 302-2-3 Clause. 8 0 to 75 V
Power Input & Current IS 302-2-3 Clause. 10 0 to 500 V, 0 to 20 A , 0 to 5000 W
Heating IS 302-2-3 Clause. 11 Ambient to 400°C
Leakage Current & Electric Strength at Operating Temperature IS 302-2-3 Clause. 13 0 to 750 µA

4) Electrical Immersion Water Heater Safety of Household and Similar Electrical Appliances

Testing Parameters Test Methods Testing Range
Transient Over Vage IS 302 (Part 1) Clause. 14 0 to 8 kV
Moisture Resistance IS 302-2-3 Clause. 15 0 to 95 %, 0 to 250°C
Leakage Current & Electric Strength IS 302-2-3 Clause. 16 0 to 5 kV, 0 to 5 V, 0 to 30 A
Abnormal Operation IS 302-2-3 Clause. 19 Upto 6 kW, Upto 30 A, Upto 250 V
Stability And Mechanical Hazards IS 302-2-3: 2007 Clause. 20 Qualitative - 60 g, Force 20 N
Mechanical Strength IS 302-2-3 Clause. 21 20 N
Construction IS 302-2-3 Clause. 22 Qualitative (Visual)
Internal Wiring IS 302-3 Clause. 23 Qualitative (Visual)
Components IS 302-2 Clause. 24 Upto 300 mm
Supply Connection & External Flexible Cord IS 302-2-3 Clause. 25 Qualitative (Visual)
Terminal For External Conductors IS 302-2-3 Clause. 26 Upto 30Amp, Upto 5V
Provision For Earthing IS 302-2-3 Clause. 27 0.1 N/ mm to 1.5 N/ mm
Screws & Connection IS 302-2 Clause. 28 0 to 300 mm, 0 to 25 mm
Clearances, Creepage Distance & Solid Insulation 1 IS 302-2-3 Clause. 29 Qualitative (Visual)
Resistance To Heat & Fire IS 302-2-3 Clause. 30 Ambient to 1200°C,
Rating IS 368 Clause. 6 Upto 500 V ac Upto 5 kW
Classification IS 368 Clause. 7 Class I & II
Marking IS 368 Clause. 8 Qualitative (Visual)
Protection Against Access to Live Part IS 302 (Part 1) & IS 302-2:201 Clause. 8 0 to 75 Vs
Power Input & Current IS 302 (Part 1) & IS 302-2:201 Clause. 10 0 to 5000 W, 0 to 230 V, 0 to 30 A
Heating IS 302 (Part 1) & IS 302-2:201 Clause. 11 0 to 400 V
Leakage Current and Electric Strength at Operating Temperature IS 302 (Part 1) & IS 302-2:201 Clause. 13 Qualitative, 0 to 750 µA,
Transient Over Voltage IS 302-2: 201 Clause. 14 0 to 8 kV
Moisture Resistance IS 302 (Part 1) & IS 302-2:201 Clause. 15 0 to 96 %, Ambient (-)250°C
Leakage Current & Electric Strength (After Moisture Test) IS 302 (Part 1) & IS 302-2:201 Clause. 16 Qualitative, 0 to 3 kV
Ecr IS 302 (Part 1) & IS 302-2:201 Clause. 27 0 to 5 V, 0 to 30 A
Overload Protection IS 302 (Part 1) & IS 302-2:201 Clause. 17 Upto 6 kW, Upto 30 A, Upto 250 V
Abnormal Operation IS 302 (Part 1) & IS 302-2:201 Clause. 19 Upto 6 kW, Upto 30 A, Upto 250 V
Stability & Mechanical Hazards IS 302-2: 201 Clause. 20 Qualitative Mass : 60 g, Force 20 N
Mechanical Strength (Drop Test) IS 302 (Part 2) & IS 302-2: 201 Clause. 21 20 N
Construction IS 302 (Part 2) & IS 302-2: 201 Clause. 22 Qualitative (Visual)
Internal Wiring IS 302 (Part 2) & IS 302-2: 201 Clause. 23 Qualitative (Visual)
Components IS 302 (Part 2) & IS 302-2: 201 Clause. 24 Upto 300 mm,
Supply Connection And External Flexible Cords IS 302 (Part 2) & IS 302-2: 201 Clause. 25 Qualitative (Visual)
Terminal For External Conductor IS 302 (Part 2) & IS 302-2: 201 Clause. 26 Qualitative (Visual)
Provision for Earthing IS 302 (Part 2) & IS 302-2: 201 Clause. 27 Upto 30 A, Upto 5 V
Screws and Connection IS 302 (Part 2) & IS 302-2: 201 Clause. 28 0.1 N/ mm to 1.5 N/ mm
Creepage Distance And Clearness Except Transient Voltage IS 302 (Part 2) & IS 302-2: 201 Clause. 29 0 to 300 mm, 0 to 25 mm
Resistance To Heat Fire and Tracking IS 302 (Part 2) & IS 302-2: 201 Clause. 30 Ambient to 1200°C
Resistance For Rusting IS 302 (Part 2) & IS 302-2: 201 Clause. 31 Qualitative (Visual)
Endurance Test IS 368 Clause. 10 Qualitative - Ambient to 300°C
Finish IS 368 Clause. 11 Qualitative (Visual)