Why Choose Delhi Test House for Wires & Cables (HT & LT)Testing?
From raw conductor materials to finished cable assemblies, we provide complete testing solutions covering electrical performance, mechanical properties, thermal endurance, fire resistance, insulation integrity, and material verification, ensuring compliance with industry standards and customer specifications.
As a NABL Accredited and BIS Recognized Testing Laboratory, Delhi Test House conducts testing in accordance with applicable Indian Standards (IS), IEC standards, and regulatory requirements, providing results trusted by manufacturers, certification bodies, government departments, consultants, and procurement agencies.
Our laboratory is equipped with modern testing instruments and specialized facilities for electrical, mechanical, thermal, ageing, flammability, insulation and safety testing, enabling accurate evaluation of cable performance under various operating conditions.
With 50+ years of testing excellence, we support cable manufacturers, power utilities, infrastructure developers, railways, telecom operators, renewable energy companies, EPC contractors, and industrial facilities with dependable testing and compliance solutions.
Our experienced engineers and technical specialists deliver accurate, technically reviewed, and traceable test reports, helping clients meet quality assurance, tender, procurement, certification, and regulatory compliance requirements with confidence.
Wires & Cables (HT & LT)Testing Services We Offer
- LT Power Cables
- HT Power Cables
- XLPE Insulated Cables
- PVC Insulated Cables
- Armoured & Unarmoured Cables
- Rubber Cables
- House Wiring Cables
- Flexible Cords
- Industrial Flexible Cables
- Appliance Wiring Materials
- Control Cables
- Instrumentation Cables
- Signal Cables
- Data Transmission Cables
- FR Cables
- FRLS Cables
- HFFR Cables
- Fire Survival Cables
- Low Smoke Zero Halogen (LSZH) Cables
- Photovoltaic (PV) Cables
- DC Solar Cables
- Renewable Energy Cable Systems
- Railway Cables
- Telecom Cables
- Solar Cables
- Underground Cables
- Industrial Cables
- Automobile Harness
Wires & Cables (HT & LT) Parameters We Test
- Conductor Resistance Test
- Insulation Resistance Test
- High Voltage Test
- Partial Discharge Test
- Tan Delta Test
- Spark Test
- Continuity Test
- Tensile Strength Test
- Elongation Test
- Cold Impact & Bending Test
- Ozone & UV Resistance
- Dynamic Penetration
- Wrapping Test
- Bending Test
- Flexibility Test
- Impact Resistance Test
- Ageing in Hot Air Oven
- Thermal Stability Test
- Heat Shock Test
- Hot Set Test
- Shrinkage Test
- Flame Retardant Test
- Vertical Flame Test
- Smoke Density Test
- Halogen Acid Gas Test
- Fire Resistance Test
- Fire Survival Test
- Insulation Thickness
- Sheath Thickness
- Overall Diameter
- Conductor Dimensions
- Mass of Zinc Coating
- Carbon Black Content
- Tensile Strength
- Elongation
- Thermal Stability
- Ageing Charcteristics
Wires & Cables (HT & LT) Testing Standards & Compliance
- S 694 – PVC Insulated Cables for Working Voltages up to and Including 1100 V
- IS 1554 (Part 1 & Part 2) – PVC Insulated Heavy Duty Electric Cables
- IS 7098 (Part 1) – XLPE Insulated Cables up to 1.1 kV
- IS 7098 (Part 2) – XLPE Insulated Cables from 3.3 kV up to 33 kV
- IS 7098 (Part 3) – XLPE Insulated Cables above 33 kV
- IS 14255 – Aerial Bunched Cables
- IS 9968 Series – Elastomer Insulated Cables
- IS 17048 – Halogen-Free Flame Retardant (HFFR) Cables
- IS 17046 – Fiber Optic Cable for Cable TV
- IS 17293 – Electric Cables for Photovoltaic Systems
- IEC 60227 Series – PVC Insulated Cables
- IEC 60502 Series – Power Cables with Extruded Insulation
- IEC 60332 Series – Tests on Electric Cable Fire Conditions
- IEC 60754 Series – Halogen Acid Gas Emission Tests
- IEC 61034 Series – Smoke Density Measurement
- IEC 60811 Series – Electric and optical fiber cables
- EN 50618 – Electric cables for Photovoltaic Systems
- IEC and other customer-specific international standards
- NABL Accredited Testing Laboratory (ISO/IEC 17025)
- BIS Recognized Testing Laboratory
- FDAS Approved Testing Laboratory
- Compliance Testing for BIS Certification Requirements
- Third-Party Quality Assurance & Product Qualification Testing
- Testing Support for Government, Utility, Railway, Infrastructure & Industrial Projects



















Sector Coverage Across the Indian Economy
Our Wires & Cables (HT & LT)Testing Process
Wires & Cables (HT & LT)Testing Services Across Delhi NCR
- Delhi
- Noida
- Greater Noida
- Ghaziabad
- Gurgaon
- Faridabad
- Sonipat
- Kundali
- Manesar
- Bhiwadi
- Jaipur
- Chandigarh
- Lucknow
- Pan India Support
Frequently Asked Questions
NABL accreditation ensures technical competence, traceability, and acceptance of test results by regulatory bodies and customers.
We test as per IS 694, IS 1554, IS 7098, IS 14255, IS 8130, IS 10810, IEC 60227, IEC 60502 and related standards.
Yes, we provide testing support for BIS compliance and certification requirements.
Turnaround time depends on the applicable standard and test scope.
Yes, sample collection and logistics support are available.
Yes, our laboratory performs fire performance, smoke density, halogen content, and flame propagation testing.
We test HT and LT power cables, XLPE cables, PVC insulated cables, building wires, flexible cables, solar cables, FR, FRLS, HFFR, LSZH, and fire survival cables.